A Sample Rescheck Compliance Certificate
Note: The specific format and content of a Rescheck compliance certificate may vary slightly depending on the software version used and local regulations. However, the core elements should remain consistent.
Rescheck Compliance Certificate Sample
Project: [Project Name]
Location: [City, State, ZIP]
Energy Code: [IECC Year]
Construction Type: [Single-family, Multifamily, etc.]
Project Type: [New Construction, Remodel, Addition]
Compliance Status: [Complies, Does Not Comply]
Compliance Details:
Conditioned Floor Area: [Square Footage]
Glazing Area: [Square Footage]
Climate Zone: [Number]
U-factor x Area (UA) Calculation: [Results]
% Better or Worse Than Code: [Percentage]
Trade-offs Used: [List of trade-offs, if applicable]
Certification:
This certificate verifies that the above-mentioned project meets the energy code requirements as calculated using Rescheck software.
[Signature] [Name] [Title] [Date]
Additional Information (May Include):
Rescheck Software Version: [Version Number]
Building Envelope Details: [Table or diagram showing wall, roof, and floor assemblies]
Energy Star Rating: [If applicable]
Other Relevant Notes: [Any additional comments or clarifications]
Example of a Compliance Status:
Complies: "The project meets the energy code requirements as calculated using Rescheck software."
Does Not Comply: "The project does not meet the energy code requirements. The following modifications are recommended to achieve compliance: [List of recommendations]"
Remember: A Rescheck compliance certificate is typically provided by a qualified professional, such as a building designer or energy consultant, who has used Rescheck software to analyze the project's energy performance.
A More Detailed Example of a Rescheck Compliance Certificate
This example provides a more detailed breakdown of the project's energy performance, including specific building envelope details and the use of energy-efficient components.
Project: Residential New Construction
Location: Houston, TX
Energy Code: IECC 2021
Construction Type: Single-family
Project Type: New Construction
Compliance Status: Complies
Compliance Details:
Conditioned Floor Area: 2,500 sq ft
Glazing Area: 500 sq ft
Climate Zone: 2
U-factor x Area (UA) Calculation:
Walls: 125 BTU/h/°F
Roof: 75 BTU/h/°F
Floors: 25 BTU/h/°F
Total: 225 BTU/h/°F
% Better or Worse Than Code: 15% better
Trade-offs Used: None
Certification:
This certificate verifies that the above-mentioned project meets the energy code requirements as calculated using Rescheck software.
[Signature] John Doe Licensed Building Designer [Date]
Additional Information:
Rescheck Software Version: Rescheck 2021
Building Envelope Details:
Walls: 2x6 framing with R-15 insulation
Roof: R-38 insulation
Floors: R-15 insulation
Energy Star Rating: 3
Other Relevant Notes: The project includes high-efficiency HVAC equipment and LED lighting.
Explanation of Terms:
U-factor: A measure of a material's ability to conduct heat. Lower U-factors indicate better insulation.
UA value: The product of the U-factor and the area of a component (e.g., wall, roof, floor).
Trade-offs: Allowable deviations from the energy code in exchange for meeting other requirements, such as using renewable energy.
For more information and to order your Rescheck Report, please click here.